Improving Productivity With Calibration
For each setup, movement of the machine spindle along each of the diagonals is done by first executing the X, then the Y and finally the Z portion of the spindle travel. Readouts are taken and recorded at each intermediate step.
Linear position errors, vertical straightness errors and horizontal straightness errors for all three linear axes, as well as three squareness errors, are measured with Optodyne's newest calibration system.
Shop managers have understood the benefits of volumetric calibration and compensation of machine tools for a while, but the technique rarely has been used because it has been too expensive and too complicated. Optodyne, Inc., of Compton, California, is now offering a volumetric calibration and compensation system that can do volumetric calibration and compensation of a single machine in about 2 to 4 hours. Optodyne officials compare this to other methods that typically take 2 business days for volumetric calibration of a machine tool, with linear calibration often requiring a full 8 hours.
This system, consisting of the MCV-500 laser calibration equipment and SD-500 Vector measurement software, is priced in the $13,000 range, making it affordable for many medium sized shops.
According to Optodyne, a regularly calibrated machine ensures high repeatability. If the machining process is correct, the parts are correct—all of the parts. And this translates into higher productivity and cost-effectiveness. So the bottom line is driving the trend toward regular volumetric calibration and compensation of metalworking machines, Optodyne officials say.
At the heart of Optodyne's calibration system is Laser Doppler Displacement Meter technology. The system measures linear position errors, vertical straightness errors and horizontal straightness errors for all three linear axes. It also measures three squareness errors. When a machine tool's volumetric errors are measured, it can be compensated over the whole volume, which improves the overall accuracy of the machine tool, not simply its linear displacement, developers say. The Optodyne system can determine volumetric accuracy with only four body diagonal displacement measurements. According to the company, body diagonal displacement errors are sensitive to all the volumetric error components and therefore make an efficient test of volumetric accuracy.
The system needs four setups to detect nine sets of errors, based on efficient measurement of body diagonals. The working volume of a typical VMC has eight body diagonals, a diagonal being defined by starting at one corner of the base plane and moving to the opposite corner at the top plane. The positive or negative axis movement defines these body diagonals. The last four body diagonals are the same corners as the first four diagonals, except the directions are reversed.
Hence there are only four body diagonal directions with forward movement and reverse movement (bi-directional), and there are only four setups.
For each setup, the machine spindle movement along each of the diagonals is measured by first executing the X, then the Y, and finally the Z portion of the spindle travel. Readouts are taken and recorded at each intermediate step. This method demonstrates how three displacement errors, three vertical straightness errors and three horizontal straightness errors are measured with only four setups. For this reason, a three-axis machine Cemented Carbide Inserts tool with a one-meter cube volume can be checked in about 4 hours.
In many applications, fixtures and tooling do not have to be removed, and enclosures do not have to be dismantled. According to the company, the system is designed so that it can be set up and operated by shop floor personnel, with two to three hours needed to learn how.
By measuring volumetric errors, Optodyne's software can generate a compensation table, which can be downloaded to the control. The table compensates for errors detected in the machine tool's whole volume. Optodyne claims that the gain in accuracy reduces the bandwidth of errors by a factor of four, going from a typical volumetric error of 0.060 mm down to 0.015 mm.
Compensation file formats are available for Giddings & Lewis, Milltronics, Siemens 840, Fanuc 15 and Fanuc 16 controls, with others in development.
Cast Iron InsertsThe Optodyne laser system is calibrated and traceable to NIST, and software analysis supports various industry standards such as ISO 230-2 and ASME B5.54. To make data collection and analysis easier, the MCV-500 can be connected to most Windows-compatible notebook or desktop computers through an RS 232 port. Windows supported software provided with the system enables automatic collection and analysis of data.
The tungsten carbide inserts Blog: https://abelhelois.exblog.jp/
MILLING INSERTS,PARTING AND GROOVING INSERTS,,Estoolcarbide.com is professional tungsten carbide cutting tools manufacturer.
by bobeileen
以前の記事
2026年 01月
2025年 12月
2025年 11月
2025年 10月
2025年 09月
2025年 08月
2025年 07月
2025年 06月
2025年 05月
2025年 04月
2025年 03月
2025年 02月
2025年 01月
2024年 12月
2024年 11月
2024年 10月
2024年 09月
2024年 08月
2024年 07月
2024年 06月
2024年 05月
2024年 04月
2024年 03月
2024年 02月
2024年 01月
2023年 12月
2023年 11月
2023年 10月
2023年 09月
2023年 08月
2023年 07月
2023年 06月
2023年 05月
2023年 04月
2023年 03月
2023年 02月
2021年 10月
2021年 09月
2021年 08月
2021年 07月
2021年 06月
2021年 05月
2021年 04月
2021年 03月
フォロー中のブログ
メモ帳
最新のトラックバック
ライフログ
検索
ブログパーツ
最新の記事
| CNC Tool Setup.. |
| at 2026-02-10 16:09 |
| What Are the C.. |
| at 2026-02-03 10:58 |
| How Do Carbide.. |
| at 2026-01-29 12:20 |
| What Makes CNM.. |
| at 2026-01-21 11:52 |
| Maximizing Too.. |
| at 2026-01-14 15:56 |